Paper
Multi-Agent Reasoning with Consistency Verification Improves Uncertainty Calibration in Medical MCQA
Authors
John Ray B. Martinez
Abstract
Miscalibrated confidence scores are a practical obstacle to deploying AI in clinical settings. A model that is always overconfident offers no useful signal for deferral. We present a multi-agent framework that combines domain-specific specialist agents with Two-Phase Verification and S-Score Weighted Fusion to improve both calibration and discrimination in medical multiple-choice question answering. Four specialist agents (respiratory, cardiology, neurology, gastroenterology) generate independent diagnoses using Qwen2.5-7B-Instruct. Each diagnosis is then subjected to a two-phase self-verification process that measures internal consistency and produces a Specialist Confidence Score (S-score). The S-scores drive a weighted fusion strategy that selects the final answer and calibrates the reported confidence. We evaluate across four experimental settings, covering 100-question and 250-question high-disagreement subsets of both MedQA-USMLE and MedMCQA. Calibration improvement is the central finding, with ECE reduced by 49-74% across all four settings, including the harder MedMCQA benchmark where these gains persist even when absolute accuracy is constrained by knowledge-intensive recall demands. On MedQA-250, the full system achieves ECE = 0.091 (74.4% reduction over the single-specialist baseline) and AUROC = 0.630 (+0.056) at 59.2% accuracy. Ablation analysis identifies Two-Phase Verification as the primary calibration driver and multi-agent reasoning as the primary accuracy driver. These results establish that consistency-based verification produces more reliable uncertainty estimates across diverse medical question types, providing a practical confidence signal for deferral in safety-critical clinical AI applications.
Metadata
Related papers
Vibe Coding XR: Accelerating AI + XR Prototyping with XR Blocks and Gemini
Ruofei Du, Benjamin Hersh, David Li, Nels Numan, Xun Qian, Yanhe Chen, Zhongy... • 2026-03-25
Comparing Developer and LLM Biases in Code Evaluation
Aditya Mittal, Ryan Shar, Zichu Wu, Shyam Agarwal, Tongshuang Wu, Chris Donah... • 2026-03-25
The Stochastic Gap: A Markovian Framework for Pre-Deployment Reliability and Oversight-Cost Auditing in Agentic Artificial Intelligence
Biplab Pal, Santanu Bhattacharya • 2026-03-25
Retrieval Improvements Do Not Guarantee Better Answers: A Study of RAG for AI Policy QA
Saahil Mathur, Ryan David Rittner, Vedant Ajit Thakur, Daniel Stuart Schiff, ... • 2026-03-25
MARCH: Multi-Agent Reinforced Self-Check for LLM Hallucination
Zhuo Li, Yupeng Zhang, Pengyu Cheng, Jiajun Song, Mengyu Zhou, Hao Li, Shujie... • 2026-03-25
Raw Data (Debug)
{
"raw_xml": "<entry>\n <id>http://arxiv.org/abs/2603.24481v1</id>\n <title>Multi-Agent Reasoning with Consistency Verification Improves Uncertainty Calibration in Medical MCQA</title>\n <updated>2026-03-25T16:22:53Z</updated>\n <link href='https://arxiv.org/abs/2603.24481v1' rel='alternate' type='text/html'/>\n <link href='https://arxiv.org/pdf/2603.24481v1' rel='related' title='pdf' type='application/pdf'/>\n <summary>Miscalibrated confidence scores are a practical obstacle to deploying AI in clinical settings. A model that is always overconfident offers no useful signal for deferral. We present a multi-agent framework that combines domain-specific specialist agents with Two-Phase Verification and S-Score Weighted Fusion to improve both calibration and discrimination in medical multiple-choice question answering. Four specialist agents (respiratory, cardiology, neurology, gastroenterology) generate independent diagnoses using Qwen2.5-7B-Instruct. Each diagnosis is then subjected to a two-phase self-verification process that measures internal consistency and produces a Specialist Confidence Score (S-score). The S-scores drive a weighted fusion strategy that selects the final answer and calibrates the reported confidence. We evaluate across four experimental settings, covering 100-question and 250-question high-disagreement subsets of both MedQA-USMLE and MedMCQA. Calibration improvement is the central finding, with ECE reduced by 49-74% across all four settings, including the harder MedMCQA benchmark where these gains persist even when absolute accuracy is constrained by knowledge-intensive recall demands. On MedQA-250, the full system achieves ECE = 0.091 (74.4% reduction over the single-specialist baseline) and AUROC = 0.630 (+0.056) at 59.2% accuracy. Ablation analysis identifies Two-Phase Verification as the primary calibration driver and multi-agent reasoning as the primary accuracy driver. These results establish that consistency-based verification produces more reliable uncertainty estimates across diverse medical question types, providing a practical confidence signal for deferral in safety-critical clinical AI applications.</summary>\n <category scheme='http://arxiv.org/schemas/atom' term='cs.AI'/>\n <category scheme='http://arxiv.org/schemas/atom' term='cs.CL'/>\n <category scheme='http://arxiv.org/schemas/atom' term='cs.LG'/>\n <published>2026-03-25T16:22:53Z</published>\n <arxiv:comment>17 pages, 6 figures. Preprint under review</arxiv:comment>\n <arxiv:primary_category term='cs.AI'/>\n <author>\n <name>John Ray B. Martinez</name>\n </author>\n </entry>"
}