Data-Driven Linearization based Arc Fault Prediction in Medium Voltage Electrical Distribution System
Authors
Mihir Sinha, Kriti Thakur, Prasanta K. Panigrahi, Alivelu Manga Parimi, Mayukha Pal
Abstract
High-impedance arc faults (HIAFs) in medium-voltage electrical distribution systems are difficult to detect due to their low fault current levels and nonlinear transient behavior. Traditional detection algorithms generally struggle with predictions under dynamic waveform scenarios. This research provides our approach of using a unique data-driven linearization (DDL) framework for early prediction of HIAFs, giving both interpretability and scalability. The proposed method translates nonlinear current waveforms into a linearized space using coordinate embeddings and polynomial transformation, enabling precise modelling of fault precursors.The total duration of the test waveform is 0.5 seconds, within which the arc fault occurs between 0.2 seconds to 0.3 seconds. Our proposed approach using DDL, trained solely on the pre-fault healthy region (0.10 seconds to 0.18 seconds) effectively captures certain invisible fault precursors, to accurately predict the onset of fault at 0.189 seconds, which is approximately 0.011 seconds (i.e., 11 milliseconds) earlier than the actual fault occurrence. In particular, the framework predicts the start of arc faults at 0.189 seconds, significantly earlier of the actual fault incidence at 0.200 seconds, demonstrating substantial early warning capability. Performance evaluation comprises eigenvalue analysis, prediction error measures, error growth rate and waveform regeneration fidelity. Such early prediction proves that the model is capable of correctly foreseeing faults which is especially helpful in preventing real-world faults and accidents. It confirms that our proposed approach reliably predicts arc faults in medium-voltage power distribution systems
Metadata
Related papers
Fractal universe and quantum gravity made simple
Fabio Briscese, Gianluca Calcagni • 2026-03-25
POLY-SIM: Polyglot Speaker Identification with Missing Modality Grand Challenge 2026 Evaluation Plan
Marta Moscati, Muhammad Saad Saeed, Marina Zanoni, Mubashir Noman, Rohan Kuma... • 2026-03-25
LensWalk: Agentic Video Understanding by Planning How You See in Videos
Keliang Li, Yansong Li, Hongze Shen, Mengdi Liu, Hong Chang, Shiguang Shan • 2026-03-25
Orientation Reconstruction of Proteins using Coulomb Explosions
Tomas André, Alfredo Bellisario, Nicusor Timneanu, Carl Caleman • 2026-03-25
The role of spatial context and multitask learning in the detection of organic and conventional farming systems based on Sentinel-2 time series
Jan Hemmerling, Marcel Schwieder, Philippe Rufin, Leon-Friedrich Thomas, Mire... • 2026-03-25
Raw Data (Debug)
{
"raw_xml": "<entry>\n <id>http://arxiv.org/abs/2602.24247v1</id>\n <title>Data-Driven Linearization based Arc Fault Prediction in Medium Voltage Electrical Distribution System</title>\n <updated>2026-02-27T18:19:56Z</updated>\n <link href='https://arxiv.org/abs/2602.24247v1' rel='alternate' type='text/html'/>\n <link href='https://arxiv.org/pdf/2602.24247v1' rel='related' title='pdf' type='application/pdf'/>\n <summary>High-impedance arc faults (HIAFs) in medium-voltage electrical distribution systems are difficult to detect due to their low fault current levels and nonlinear transient behavior. Traditional detection algorithms generally struggle with predictions under dynamic waveform scenarios. This research provides our approach of using a unique data-driven linearization (DDL) framework for early prediction of HIAFs, giving both interpretability and scalability. The proposed method translates nonlinear current waveforms into a linearized space using coordinate embeddings and polynomial transformation, enabling precise modelling of fault precursors.The total duration of the test waveform is 0.5 seconds, within which the arc fault occurs between 0.2 seconds to 0.3 seconds. Our proposed approach using DDL, trained solely on the pre-fault healthy region (0.10 seconds to 0.18 seconds) effectively captures certain invisible fault precursors, to accurately predict the onset of fault at 0.189 seconds, which is approximately 0.011 seconds (i.e., 11 milliseconds) earlier than the actual fault occurrence. In particular, the framework predicts the start of arc faults at 0.189 seconds, significantly earlier of the actual fault incidence at 0.200 seconds, demonstrating substantial early warning capability. Performance evaluation comprises eigenvalue analysis, prediction error measures, error growth rate and waveform regeneration fidelity. Such early prediction proves that the model is capable of correctly foreseeing faults which is especially helpful in preventing real-world faults and accidents. It confirms that our proposed approach reliably predicts arc faults in medium-voltage power distribution systems</summary>\n <category scheme='http://arxiv.org/schemas/atom' term='eess.SY'/>\n <published>2026-02-27T18:19:56Z</published>\n <arxiv:primary_category term='eess.SY'/>\n <author>\n <name>Mihir Sinha</name>\n </author>\n <author>\n <name>Kriti Thakur</name>\n </author>\n <author>\n <name>Prasanta K. Panigrahi</name>\n </author>\n <author>\n <name>Alivelu Manga Parimi</name>\n </author>\n <author>\n <name>Mayukha Pal</name>\n </author>\n </entry>"
}