Paper
FaultXformer: A Transformer-Encoder Based Fault Classification and Location Identification model in PMU-Integrated Active Electrical Distribution System
Authors
Kriti Thakur, Alivelu Manga Parimi, Mayukha Pal
Abstract
Accurate fault detection and localization in electrical distribution systems is crucial, especially with the increasing integration of distributed energy resources (DERs), which inject greater variability and complexity into grid operations. In this study, FaultXformer is proposed, a Transformer encoder-based architecture developed for automatic fault analysis using real-time current data obtained from phasor measurement unit (PMU). The approach utilizes time-series current data to initially extract rich temporal information in stage 1, which is crucial for identifying the fault type and precisely determining its location across multiple nodes. In Stage 2, these extracted features are processed to differentiate among distinct fault types and identify the respective fault location within the distribution system. Thus, this dual-stage transformer encoder pipeline enables high-fidelity representation learning, considerably boosting the performance of the work. The model was validated on a dataset generated from the IEEE 13-node test feeder, simulated with 20 separate fault locations and several DER integration scenarios, utilizing current measurements from four strategically located PMUs. To demonstrate robust performance evaluation, stratified 10-fold cross-validation is performed. FaultXformer achieved average accuracies of 98.76% in fault type classification and 98.92% in fault location identification across cross-validation, consistently surpassing conventional deep learning baselines convolutional neural network (CNN), recurrent neural network (RNN). long short-term memory (LSTM) by 1.70%, 34.95%, and 2.04% in classification accuracy and by 10.82%, 40.89%, and 6.27% in location accuracy, respectively. These results demonstrate the efficacy of the proposed model with significant DER penetration.
Metadata
Related papers
Fractal universe and quantum gravity made simple
Fabio Briscese, Gianluca Calcagni • 2026-03-25
POLY-SIM: Polyglot Speaker Identification with Missing Modality Grand Challenge 2026 Evaluation Plan
Marta Moscati, Muhammad Saad Saeed, Marina Zanoni, Mubashir Noman, Rohan Kuma... • 2026-03-25
LensWalk: Agentic Video Understanding by Planning How You See in Videos
Keliang Li, Yansong Li, Hongze Shen, Mengdi Liu, Hong Chang, Shiguang Shan • 2026-03-25
Orientation Reconstruction of Proteins using Coulomb Explosions
Tomas André, Alfredo Bellisario, Nicusor Timneanu, Carl Caleman • 2026-03-25
The role of spatial context and multitask learning in the detection of organic and conventional farming systems based on Sentinel-2 time series
Jan Hemmerling, Marcel Schwieder, Philippe Rufin, Leon-Friedrich Thomas, Mire... • 2026-03-25
Raw Data (Debug)
{
"raw_xml": "<entry>\n <id>http://arxiv.org/abs/2602.24254v1</id>\n <title>FaultXformer: A Transformer-Encoder Based Fault Classification and Location Identification model in PMU-Integrated Active Electrical Distribution System</title>\n <updated>2026-02-27T18:28:12Z</updated>\n <link href='https://arxiv.org/abs/2602.24254v1' rel='alternate' type='text/html'/>\n <link href='https://arxiv.org/pdf/2602.24254v1' rel='related' title='pdf' type='application/pdf'/>\n <summary>Accurate fault detection and localization in electrical distribution systems is crucial, especially with the increasing integration of distributed energy resources (DERs), which inject greater variability and complexity into grid operations. In this study, FaultXformer is proposed, a Transformer encoder-based architecture developed for automatic fault analysis using real-time current data obtained from phasor measurement unit (PMU). The approach utilizes time-series current data to initially extract rich temporal information in stage 1, which is crucial for identifying the fault type and precisely determining its location across multiple nodes. In Stage 2, these extracted features are processed to differentiate among distinct fault types and identify the respective fault location within the distribution system. Thus, this dual-stage transformer encoder pipeline enables high-fidelity representation learning, considerably boosting the performance of the work. The model was validated on a dataset generated from the IEEE 13-node test feeder, simulated with 20 separate fault locations and several DER integration scenarios, utilizing current measurements from four strategically located PMUs. To demonstrate robust performance evaluation, stratified 10-fold cross-validation is performed. FaultXformer achieved average accuracies of 98.76% in fault type classification and 98.92% in fault location identification across cross-validation, consistently surpassing conventional deep learning baselines convolutional neural network (CNN), recurrent neural network (RNN). long short-term memory (LSTM) by 1.70%, 34.95%, and 2.04% in classification accuracy and by 10.82%, 40.89%, and 6.27% in location accuracy, respectively. These results demonstrate the efficacy of the proposed model with significant DER penetration.</summary>\n <category scheme='http://arxiv.org/schemas/atom' term='eess.SY'/>\n <category scheme='http://arxiv.org/schemas/atom' term='cs.AI'/>\n <category scheme='http://arxiv.org/schemas/atom' term='cs.LG'/>\n <published>2026-02-27T18:28:12Z</published>\n <arxiv:primary_category term='eess.SY'/>\n <author>\n <name>Kriti Thakur</name>\n </author>\n <author>\n <name>Alivelu Manga Parimi</name>\n </author>\n <author>\n <name>Mayukha Pal</name>\n </author>\n </entry>"
}